It is necessary to be able to display and save the value of each monitoring parameter of the main incoming line of each distribution cabinet in real time, and display and save the working status of each monitored switch in real time. Set the upper and lower limit values ​​of voltage and current. When the monitored voltage or current exceeds the set allowable value, the system is diagnosed as a fault (alarm) event, and the monitoring main system should immediately pop up the corresponding alarm page window At the same time, the monitoring host sends out multimedia sound alarm or telephone automatic dialing alarm to notify the staff on duty or the corresponding supervisor. You can query the historical records of any monitoring object.
2. UPS equipment:
Real-time display and save the operating parameters and status of each component that can be monitored remotely provided by each UPS communication protocol. Real-time judge whether the UPS component has an alarm. When a component of the UPS fails or exceeds the limit, the monitoring main system immediately pops up the corresponding alarm page window. At the same time, the monitoring host sends out a multimedia sound alarm or automatic dialing alarm of the phone to notify the staff on duty or the corresponding Supervisor. You can query the historical records of any monitoring object.
3. Precision air conditioning system:
Monitor the operation status of the precision air conditioner, use graphics and color changes to display the working condition of the air conditioner, and alarm when there is a failure. Monitoring and alarming of the operating state of the air conditioner's refrigerator, compressor high-pressure failure, filter clogging, etc., to detect the operating state of the air conditioner. The monitoring system can be used to control the start and stop of the air conditioner in the remote monitoring room and change the setting values ​​of temperature and humidity.
Real-time display and save the operating parameters, status of various components and alarm conditions provided by each air-conditioning communication protocol that can be monitored remotely. During the alarm, the alarm can be distinguished by the change of the corresponding color in the pop-up alarm window. At the same time, the system will send out a multimedia sound alarm or a telephone automatic dialing alarm to notify the staff on duty or the corresponding supervisor. You can query the historical records of any monitoring object.
4. Ambient temperature and humidity system:
Real-time display (electronic map mode) and record the indoor temperature and humidity values ​​detected by each temperature and humidity sensor, and display a graph of changes in a short period of time. The system can set the upper and lower limits of the temperature and humidity of each temperature and humidity sensor.
When the data detected by any temperature and humidity sensor exceeds the set upper or lower limit, the system immediately pops up the corresponding alarm window, and at the same time, the monitoring host issues a multimedia sound alarm or automatic dialing alarm of the phone to notify the on-duty personnel or the corresponding supervisor. You can query the historical records of any monitoring object.
V. Fire fighting system interface:
Real-time display and save the operating parameters, status of various components and alarm conditions provided by the intelligent fire host communication protocol that can be monitored remotely. When alarming, the system will send out multimedia sound alarm or telephone automatic dialing alarm to notify the staff on duty or the corresponding supervisor. You can query the historical records of any monitoring object.
6. Leakage monitoring system:
When the air conditioner or the water pipe along the line leaks, the system will pop up the corresponding alarm window, and there will be a corresponding text box to indicate the location of the leak; at the same time, it will also use the multimedia sound alarm or telephone automatic dialing alarm to notify the staff on duty or the corresponding supervisor . You can query the historical records of any monitoring object.
7. Access control management:
The non-contact induction card is used to control and record the personnel entering the computer room. One card per person is authorized by the card management system to enter different areas. Record and display the entrance and exit door management data from each entrance and the door opening and closing status. When a person swipes the card to enter the door, the system immediately pops up the corresponding access control record management window, and at the same time, the corresponding cardholder's photo and management information can be popped up at the same time (the exit information may not be displayed when the exit button is pressed to exit). In the entry and exit data, the cardholder's entry time, card number, cardholder's name, affiliation, and the name of the entry and exit are displayed.
Eight, the drawbacks of virtualization
When you purchase a monitoring solution, it is important to remember certain factors, such as virtualization, which can complicate the monitoring process. For example, there are various monitoring application software on the market that can monitor server hardware failures. This kind of application software may prompt the server temperature that exceeds the standard, SMART disk warning or cooling fan failure in the server. The problem is that if the monitoring solution cannot know that they are monitoring virtual machines, it cannot know that the hardware system has a potential impact on server availability.
The monitoring software should deal with problems with the main server hardware. But if the main server is in danger, then any virtual machine running on the host also faces the same problem. Therefore, if your enterprise wants to deploy virtual machines, you must find a way to distinguish between physical servers and virtual servers, and understand which virtual machine is running on which main server. In the event of hardware failure, you must also have the ability to quickly migrate client servers to different primary servers.
Finally, management and monitoring are closely related. Only companies with perfect management capabilities can ensure that monitoring functions. For example, if the administrator has no way to solve the failure of the server in the event of failure, the monitoring software tells you what is going to happen. So what will be the best The combination of remote management of components is very important.
Low Voltage SWA Armored Cable, also known as Steel Wire Armored Cable, is a type of electrical cable that is used for the transmission of low voltage electrical power. It is commonly used in applications where the cable needs to be protected from mechanical damage, such as underground installations or in areas with high levels of physical stress.
The SWA Armored Cable consists of multiple conductors, usually made of copper or aluminum, which are insulated and then wrapped in a layer of steel wire armor. The steel wire armor provides protection against external forces, such as impact or crushing, and also acts as a grounding conductor.
The cable is typically designed for voltages up to 1000 volts and is available in various sizes and configurations to suit different applications. It is commonly used in industrial, commercial, and residential settings for power distribution, lighting, and control systems.
Some of the key features and benefits of Low Voltage SWA Armored Cable include:
- Mechanical Protection: The steel wire armor provides excellent protection against physical damage, making it suitable for installations in harsh environments or areas with high levels of mechanical stress.
- Electrical Protection: The armor also acts as a grounding conductor, providing protection against electrical faults and ensuring safe operation.
- Durability: The cable is designed to withstand extreme temperatures, moisture, and UV exposure, making it suitable for both indoor and outdoor installations.
- Easy Installation: The armored construction of the cable makes it easy to handle and install, reducing installation time and costs.
- Versatility: The cable is available in various sizes and configurations, allowing for flexibility in design and installation.
Overall, Low Voltage SWA Armored Cable is a reliable and durable solution for low voltage power transmission, offering excellent mechanical and electrical protection. It is widely used in a range of applications and environments, providing a safe and efficient electrical system.
SWA Armored Cable,Copper Sheathed Power Cable,Low Voltage XLPE Power Cable,PVC Insulation SWA Armored Power Cable,Low Voltage Multi Core SWA Armored Cable
Ruitian Cable CO.,LTD. , https://www.hbruitiancable.com